smw file is able to be opened and changed using SimplWindows. Earlier versions of Control systems did not save the newly loaded program until you selected to The difference being is that the 2-Series will overwrite the existing program automatically UNLESS you elect to save it prior. Inside the SIMPL folder you will find a complete example program that can be used to start playing with the module. The module implements an http (api) interface to send data to SIMPL Windows. spz file that can then be reloaded to a same model processor. This module has been created to make it easy for services that have an http client API to send data to a Crestron control systems. You are then prompted for a Save-As filename and location to save the extracted. To extract the compiled program from a 2-Series processor:Ĭheck select the Select, browse to the desired file having the. To upload a new program to any type processor:

Note: A compiled 2-Series processor program can be extracted to then be reloaded into another processor, however it can not be opened in SimplWindows or modified in any way, shape or form. You cannot work with/ edit/ modify or change in any way a compiled program. spzĪ compiled X-Series, ST-CP or CNMS processor file extension is.

SBC Yahoo! DSL - Now only $29.The program file that is loaded into a Crestron Control processor is a compiled file and can not be modified.Ī compiled 2-Series processor file extension is. Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service. Do I need all 3 or just the serial driver If I just double click on the Lexicon MC-8 module it opens into simpl windows without any problem at all. I tried putting the module into crestron/simpl/userdb and rebuilding the database, but it does not appear. The database so I can use it in my already created program.Īlso, the Lex MC-8 module has 3 components, which I was windows to open while I have my simpl program open.

Simpl windows without any problem at all. If I just double click on the Lexicon MC-8 module it opens into Rebuilding the database, but it does not appear. I tried putting the module into crestron/simpl/userdb and Windows to open while I have my simpl program open. Section of the files area here, but I am not sure how to get simpl Hukalaki wrote:i have found the MC-8 serial control module on the "modules" Also keep in mind that the module name is derived from the program header 'name' and not from the file name. Make sure you have clicked on both x-gen and 2 series. If the module in question was 'saved as' a module for x-gen processor alone it won't show while programming a 2 series processor.